CQ Soil Testing Brisbane provides a comprehensive wastewater and septic design service, including all necessary fieldwork, testing, and design in accordance with Australian Standard AS/NZS 1547: On-site Domestic Wastewater Management. We provide expert advice on the most suitable wastewater or septic system for your site, ensuring you meet compliance requirements.

OSSF - On Site Sewerage Facility
If you are planning to purchase land for a new home, it’s important to check before you buy. If a reticulated sewerage system is not available, you will need to consider an OSSF (On-Site Sewerage Facility).
Your first step should be to obtain advice from your local council and CQ Soil Testing Brisbane, so you can understand the requirements and suitability of the site before making a decision.

How to Protect Groundwater
Groundwater (usually sourced from bores) has been used for decades, but only more recently have we come to understand how vulnerable it is to contamination from surface activities. Effluent from an OSSF can find its way into groundwater, making it vital to locate systems a safe distance from wells, bores, creeks, lakes, and dwellings, and to ensure they are properly maintained.
A failing OSSF can release chemicals such as medicines, pesticides, paints, varnishes, and thinners into local groundwater. Even small amounts of these substances can pose serious risks to public health and the environment. Certain geological conditions, such as fractured bedrock and shallow groundwater tables, can also allow bacteria and viruses to travel rapidly and contaminate drinking water supplies.
Groundwater is highly susceptible to contamination, so correct system design and placement are essential.
A site report from CQ Soil Testing Brisbane enables the proper design of a new system, helping ensure your groundwater is protected for both current and future generations.

Deciding Which System is Best?
When selecting an OSSF, consideration must be given to the site conditions and the design loading generated by the dwelling. In accordance with Australian Standard AS/NZS 1547: On-site Domestic Wastewater Management, the selection of an appropriate system depends on factors such as the site’s suitability for effluent absorption, available land area, and expected water usage.
Site conditions, including soil type, local rainfall, and depth to groundwater, are also key factors in determining system design and location, and are assessed by our team.

Questions to Ask About a Septic System When Buying an Existing Home
If you are buying an existing home, it is important to ask the seller key questions about the septic system, including:
- How old is the septic system?
- When was the tank last pumped out and de-sludged?
- How frequently has the system been maintained?
- Have there been any signs of system failure?
- Have there been any additions or changes to the property that may require an upgrade to the system?

Septic Tanks
A properly functioning septic tank operates as a biological system, where naturally occurring bacteria break down and digest waste, producing primary-treated effluent. This effluent is then further treated through the surrounding soil.
Health caution: Septic tanks do not eliminate pathogenic bacteria, viruses, or parasites. Effluent must be handled with care, and contact with people, food, clothing, and pets should be avoided. Appropriate protective clothing should be worn, and hands should be thoroughly washed after any contact.
A well-functioning septic tank typically consists of three distinct layers:
- A top layer of fats and oils (scum), which floats on the surface
- A middle layer of partially clarified liquid (effluent)
- A bottom layer of settled solids (sludge or biosolids), which accumulates over time

The scum layer helps prevent odours from escaping and limits air entering the tank. As new wastewater enters, treated effluent flows out through an outlet pipe.
In most septic systems, effluent is discharged directly into the soil via pipes and trenches (an absorption field). Where soils are shallow or unsuitable, alternative systems may be required, such as raised mounds, evapotranspiration beds, or modified absorption fields. At this stage, the effluent still contains dissolved pollutants, including nutrients (such as nitrogen and phosphorus), as well as disease-causing pathogens (including viruses, bacteria, and parasites).
Within the absorption field, natural soil processes reduce pathogens and break down some nutrients via aerobic and anaerobic bacteria. This process is very slow, so it is important not to overload the system with excessive wastewater. Over time, the effluent is absorbed by the soil, taken up by vegetation, evaporated, or percolates into the groundwater. A risk can arise if effluent moves across the surface or through subsoil pathways into drainage lines, creeks, or rivers. When starting a new or recently pumped system, the tank should be filled with clean water. A small amount of lime may be added over several days to help manage odours and support favourable conditions for bacterial activity.
Greywater Tanks and Grease Traps
These systems are typically only accepted when composting toilet sytems are planned. Greywater is wastewater generated from the kitchen, laundry, and bathroom. A grease trap may also be installed to collect oils and fats from kitchen wastewater before it enters the system.
Greywater typically flows into a greywater treatment system, then discharged to a subsurface land application area (trench, bed or ETA).
In accordance with Australian Standard AS/NZS 1547: On-site Domestic Wastewater Management, untreated greywater is generally applied below ground via subsurface irrigation systems. Above-ground discharge is only permitted where the wastewater has been treated to an appropriate standard and approved by the relevant authority.
Queensland local council requirements must also be considered, as specific design, installation, and approval conditions may vary between regions.

Evapotranspiration Beds
Evapotranspiration beds are used where soil conditions are unsuitable for conventional absorption trenches, such as in shallow, or low permeable soils. These systems rely on evaporation and plant transpiration to dispose of wastewater.
They are typically suited to climates where evaporation exceeds rainfall, allowing effluent to be removed to the atmosphere rather than infiltrating into the soil or groundwater.

AWTS - Aerated Wastewater Treatment Systems
Effluent from an Aerated Wastewater Treatment System (AWTS) is treated to a secondary standard suitable for land application.
An AWTS typically consists of multiple treatment stages, often within a single unit. The first stage is a primary chamber where solids settle and anaerobic digestion occurs. This is followed by an aeration chamber, where air is introduced to promote aerobic bacterial activity and further break down organic matter. The effluent then passes through a clarification stage before being disinfected, commonly using chlorine or ultraviolet (UV) systems.
Following treatment, the effluent is pumped to a designated irrigation (surface or subsurface) or subsurface (trench, bed or ETA) land application area (LAA). Irrigation is typically via subsurface systems, such as drip irrigation, although surface spray systems may be permitted in some cases depending on site conditions and local council requirements. Irrigation LAA’s typically require more area than tradition subsurface disposal methods. Traditional subsurface systems include absorption trenches and beds, and evapotranspiration and absorption beds (ETA). These systems are typically used where sites are constrained by available land area.
The additional treatment provided by an AWTS significantly reduces pathogen levels and improves effluent quality, provided the system is properly maintained and the disinfection unit is functioning effectively.
In Queensland, AWTS owners are required to have a service contract in place with a qualified technician, with regular servicing (typically quarterly) and reporting to the local council to ensure ongoing compliance.